AELAB GUANGZHOU CO.,LTD, A & E Lab Instruments (Guangzhou) Co.,Ltd510230About Us2504,No.2-6 Hongde Road, Guangzhou, Guangdong, China.AELAB Group major supply lab & medical instruments, we have our own brand and trading the machines together. AELAB own brand machines can follow customer requires make OEM/ODM design. Also, if your have any project or tender issue, we can provide one-step purchasing solution. We gained SGS/ISO and the products have been CE/RoHs/FC/UL certificated.
We are focus to develop and market our products through distributors. Our technical engineers are able to help you choose the most suitable products to meet your requirements. All products are guaranteed by warranty. Our machine has been greatly used by hos
+ The TANK microwave digester has been adhering to the principle and concept of "safe experiement", "efficient and convenient operation" and "durable use" from R&D to production. It can be widely used in routine laboratories and also applied under extreme conditions. + TANK adopts advanced dual magnetron non-pulse frequency microwave heating technology, realizing the high power microwave heating & homogeneous heating; + TANK has more than 20 safety guarantee technologies to ensure that TANK has high level of safety performance and data accuracy; At the same time, TANK's highly intelligent man-machine dialogue operation system and wireless control module make the experiment process become efficient, convenient and humanized, and bring safe and comfortable experience to users. + 12-vessel High-throughput processing capacity, meeting the needs of all kinds of sample preparation; + Advanced multicore integrated optical fiber temperature control system, with precise temperature control and uniform digestion;
+ The quartz digestion vessel enables the digestion process to be visible. + Initiative wireless remote video monitoring system, together with quartz vessels, makes the reaction be seen clearly at a glance. Pictures and videos can be taken during the entire process; + 500 ml ultra-large digestion vessel meets the special requirements for the digestion of samples of up to 10 grams. + The drying rotor aides in the drying process of samples, + It is patented safety bolt design eliminates the need for explosion-proof membranes and other costly consumables. + The Aerospace composite fiber outer vessel ensures the highest level of vessel security. + Large 65L stainless steal chamber and dual magnetron structure, is designed for high energy and uniform microwave field. + With over 20 years of experience in the industry it is known asa innovation leader with numerous patents.
+ MDS-6G microwave digestion/extraction/synthesis system (nickname: SMART), a subversion of tradition, is a market-oriented practical compact microwave digester made by us with its over 20 years' experience; + It highlights the company's three major ideas of product design and also meets users' needs in "safety", "durability" and "convenience of operation." + The outer vessel of SMART exclusively made by ultrastrength aerospace composite fiber is invincible in anti-explosion, and its performance indicators such as corrosion resistance, high temperature/impact/pressure resistance are far better than that of the widely used modified PEEK engineering plastics vessel (this material is fusible at high temperature, fragile at high pressure and explosive by chemical corrosion). + The compressive strength of aerospace composite fiber is up to 10000psi and temperature 500-600℃, fundamentally eliminating safety risks to operator in use.
+ More than 20 years of experience in microwave; + Leader in number of users nationally of 9000+ units; + 6-year supplier of Administration of Quality Supervision, Inspection and Quarantine of P.R.C; +100 vessel throughput, NO.1 in the world; + 4 times BCEIA gold award of China Association for Instrumental Analysis; + Various choices of vessel configurations, throughput of: 16, 18, 40 and 100 vessels; volume of: 15ml, 30ml, 50ml, 70ml, 100ml, 200ml and 500ml; + Free lifetime warranty to the core components-magnetron of the Microwave Digestion System;
+ Satisfy the requirements of different samples' digestion / extraction processing; + Up to 12 vessels high-throughput processing capacity; + Exclusive patented multifunctional safety bolt design, instead of explosion-proof membrane and other consumables + Aerospace composite fiber outer vessel-the highest level of security measures; + Large-screen color software interface, clear and direct-viewing in operation, bright in appearance and smart in performance. +Connected to and controlled by computer, achieving secure remote operation, and unlimited program storage database; + Small volume VS big chamber, which is advance in industrial design and provides perfect experience; + Free lifetime warranty to the core components - magnetron of the microwave Digestion System; + 20 years of industry experience with no life injury; + Won China’stop award-BCEIA GOLD four times and leads in the number of users nationally;
+ Up to 12 vessels to meet different digestion requirements. + Vertical Microwave design for even distribution of microwave. + Real time monitoring for both temperature and pressure of each vessel. + Contactless monitoring with no burst disk design saves consumable cost and maintenance cost. + Imported vessel material for both sample vessel and protection vessel ensures safety. + Touch screen with user-friendly interface for easy operation. + Imported CFRP with high strength ensures impact resistance. + Pre-installed international standard methods while user can also edit, save, modify and delete own method. + 316L stainless steel tank with teflon coating avoids erosion and ensures fast cooling. + Special magnetron design which carries out high microwave leakage standards.
+ Vent and Self-reseal digestion vessel: self-vent and reseal structure with patented law ensures that vessels will release pressure and instantly reseal when a sudden over-pressurization occurs. This prevents waste of batch samples and solutions, and also avoids sample vessel damage. + Temperature-pressure monitoring/protection system: Advanced contactless temperature control technology which measures real temperature of solution in each digestion vessel. Meanwhile, it adopts multi-fiber to monitor pressure in a contactless way. This realizes isolation between temperature and pressure control system, avoids cross-contamination of all samples and also ensures temperature and pressure monitor and control for each and every vessel. All temperature and pressure data are displayed in real time during the microwave rum, allowing a visual check of digestion conditions. It prevents over-pressurization and over-heating + Large storage capacity: can edit and store 255 programs according to user's requirements and each method program can set 10 digestion steps. Users can set parameters (temperature, pressure, time, microwave power) according to their own requirements which provides convenient operation for users. + Multi safety protection functions: high strength double security door, temperature monitoring, high temperature prevention, pressure monitoring, high pressure prevention, instruments fault monitoring alert, innovative stopping running when opening door, instruments abnormal sound monitoring. + Power and power regulation mode: using variable frequency resonance or non-pulse (optional) continuous rotating mode to ensure highly efficient and even microwave throughput. Users can adjust it according to users' requirement between 0-3000W.
+ Over 70 elements can be measured + Fast analysis, 5-8 elements per minute + Excellent detection limits, at ppb level for most elements + Wide linear dynamic range, reaching 6 orders of magnitude, from ppb to percentage + Lower gas consumption; Each argon gas cylinder can be used for 8 hours + Rare earth metal + Silicon materials, magnetic materials processing industry + Metallurgical industry: analysis of impurity elements influencing the quality of metal materials Water quality control + Geology, mineral + Petrochemical: measurements of more than 30 elements in crude oil + Pharmacy, hygiene, agriculture, environmental protection, commodities and food industry
+ Built-in eluent generator, free from configuring eluent, with gradient elution available; + Modular manufacturing process to maintain excellent systemic stability; + Built-in low-pressure degassing technology to eliminate bubble interference for more stability; + Optional intelligent automatic injection system for large sample volumes, which features automatic dilution to save labor and time;Work across a variety of detectors, to expand the scope of applications of ion chromatography.
+ Temperature-control bipolar conductivity detector Greater detection range,better precise analysis. + Built-in circulating 3D constant temperature technology Temperature stability time is less than 30 mins, ensuring the accuracy and reliability of test data + The world's leading full-range series of ion chromatographic columns High efficiency, large capacity of the columns for detecting ions of varied compositions + Self-Regenerating Electrolytic Micro-membrane Suppressor. + High pressure resistance, small dead volume, highly responsive to signals + Able to detect anions and cations at the ppb level + Work across a variety of detectors, to expand the scope of applications of ion chromatography.
+ CIC-D100 ion chromatograph is a classic product of AELAB, which has been accepted by many customers. Based on the latest needs of users, Shenghan produced a newly upgraded CIC-D100. + Compared with the previous one, it is more accurate and reliable. The new IC not only can detect anions, cations and other polar substances in different matrix samples, but also separate ions with four orders of magnitude difference. + Intelligent maintenance function is added to give users a better experience. It is suitable for third-party testing institutions, enterprises, environmental protection, chemical industry, mining and metallurgy and other fields.
IAS-3120 NIR Spectrometer is capable of analyzing samples in powder, granule, or liquid form. It can be used for testing and analysis of crops, animal feed, foodstuff and other products in agriculture, dairy, pharmaceutical and chemical industries. It may measure composition of protein, fat, moisture, ash content, fiber, etc. The device is compact and easily portable to used either on-site or in-lab.
+ Two operation mode could be chosen: fluorescence intensity and luminous intensity. Fluorescence scanning, kinetic determination and quantity analysis could be done under fluorescence intensity mode. + 365nm exciting wavelength Raman peak of water in 1 cm quartz fluorescence cuvette S/N≥150 High performance sensitivity simplifies the measurement of low detective sample. + 10 stages gain adjustment could be chosen for emission spectrum scanning, including high speed low S/N scanning and precise scanning. Total spectrum scanning could be done in 1 second. With the intelligent pre scanning feature, unknown sample's spectrum information could be detected rapidly. Auto-omission of the influence of scattering peak and harmonic peaks, it ensure the best measurement parameters and locate the fluorescence emission peak. +Support off-line mode and on-line mode. Under off-line mode, instrument's computer system offer the fluorescence intensity measurement, concentration direct reading, auto 0 adjustment, auto background subtraction and etc. Under on-line mode, we could use quality and quantity software to control data acquisition and analysis through USB2.0 interface. + High stable and long life 150W xenon lamp and power source ensure high stable testing and wide range of spectrum. + The normalized feature for fluorescence value could make different fluorescence's result comparable. + Provide optional PC qualitative and quantitative software package with expansible time scanning, wavelength scanning, graphic calculation and storage-access abilities。 + Optional accessories for different measurement, including single hole cell holder, fluorescence sample holder for different features, 200μl micro scale centrifuge tube, micro scale capillary sample holder, semi-auto sample introduction accessories, membrane sample accessories, powder sample accessories, jacket sample accessories and etc.
+ High sensitivity optical system: cube-corner Michelson interferometer combined with patented fixing mirror alignment technology, to ensure long term stability, without the need of dynamic alignment which needs extra complicated electronic circuits. Reflecting mirrors are coated with gold to provide the maximum light throughput and ensure the detection sensitivity. + High stability modular partition design: compact structure modular design with layout on cast aluminum base and overall balance of mechanical robustness and partition heat dissipation, offering higher ability of deformation resistance and less sensitive to vibrations and thermal variations, greatly improves the mechanical stability and long term working stability of the instrument. + Intelligent multi-sealed moisture-proof design: multiple sealed interferometer, large-capacity desiccant cartridge with visible window and easy replacement structure, real-time monitoring of temperature and humidity inside the interferometer, getting rid of influences of high temperature, high humidity and chemical corrosions to the optical system in many ways. + Innovated integration electronic system: high sensitivity integrated DLATGS detector pre-amplifier technology, dynamic gain amplification technology, high precision 24-bit A/D conversion technology, real-time control and data processing technology, digital filter and network communication technology, ensuring high quality real-time data collection and high-speed transmission. + Good anti-electromagnetic interference capability: The electronic system is designed to meet CE certification and electromagnetic compatibility requirements, minimizing electromagnetic radiation in design and technology,in line with green instrument designing concept.
+ The new upgraded pump reserves the classic reciprocating parallel pump design to provide accurate flow and minimize pressure fluctuations. + The structure of one-piece check valve is simple and provides excellent leak resistance. + The piston rod can be retracted automatically so you to replace the piston seal easily without opening the instrument case. + New piston rinse function adopts dual-piston seals design, it is provided for buffer salt systems. + Less noise and higher reliability. + Extended warranty service and more comprehensive after-sales service to assist with your analysis. + Specifications of Infusion Unit.
+ LC-80 ChroMini HPLC is designed to fit the needs of uses in special fields, such as Chemical industry, agricultural feed, teaching and training. As a cost-effectiveand integratedliquid chromatograph, the installation, operating, service and moving of LC-80 ChroMini HPLC is more convenience. On the basis of the analysis needs for food and feed industry, We have developed various application packages, such as fat-soluble vitamins, water soluble vitamins, amino acid analys is,clenbuterol,melamine, aflatoxin, be nzopyrene and Sudan III etc. + LC-80 high performsnce liquid chromatograph is a brand new chromatographic instrument of high accuracy. The intergration, the modularity and the intelligence are all in this instrument of a small size with the convinence of maintenance and free mobility. + Adoption of the leading technology of microcomputer makes the control of unit with just the connection to the PC chromatographic working station possible. Simplification of operation will emancipate you from the hard work in the laboratory! +Intergration reduces the distance of tubing between units and the quantity of interface. Thereby the reduction of dead volume and potential leaking point improves the overall performance and meanwhile provides a convinent maintenance.
+ PC System is used to control the instrument. Preinstalled AA-Win 3.0 software, user manuals, cook book and Windows operating system. + AA-Win 3.0 software provides full control of the instrument and autosampler with easy method change for each technique. + Automatic 8 Hollow Cathode lamp turret controlled and optimised by the AA-Win 3.0 software. Operating lamp current and warm-up lamp current can be individually controlled to eliminate drift commonly associated with lamp warming. + D2 lamp background correction system fitted as standard to all configurations. High energy D2 lamp and adjustable beam splitter mirror are optimised by the AA-Win 3.0 software. + Self Reversal background correction system fitted as standard to all configurations. The high performance background system uses the same hollow cathode lamp as installed for the analysis. Minimum extra components are required and optical alignment is very simple. Self Reversal can be used for any element at any wavelength making it extremely versatile. + High precision minimal optics ensures maximum light throughput to the computer controlled Czerny-Turner monochromator. + A universal autosampler is available as an optional accessory which is conveniently mounted on the front of the A3 instrument. + Absorption and Emission modes are standard features in the AA-Win3.0 software as well as peak height, peak area, sequential and manual integration modes
+ The instrument has a motorised 8 hollow cathode lamp turret which allows the automatic positioning and optimisation of each hollow cathode lamp by the software. + The control of the gas flows for the fuel gas (C2H2) of the burner is also carried out directly from the software thus allowing optimisation of the instrument for the best analytical parameters for a selected analysis. + Two methods of background correction are available. The first utilises a Deuterium Arc lamp and the second is the proven method of Self Reversal. + High precision minimal optics ensures maximum light throughput to the computer controlled Czerny-Turner Monochromator. + The location of the wavelength and peak selection is automatically controlled from the software. + The spectral bandwidth is automated and is available with a choice of five slit sizes. + The electronic parameters for the photomultiplier tube detector, the hollow cathode lamp current and the balancing of the absorbance and background energies are controlled from the software. + The ignition of the flame is computer controlled and the various safety interlocks offer a very safe operating system.