AELAB GUANGZHOU CO.,LTD, A & E Lab Instruments (Guangzhou) Co.,Ltd510230About Us2504,No.2-6 Hongde Road, Guangzhou, Guangdong, China.AELAB Group major supply lab & medical instruments, we have our own brand and trading the machines together. AELAB own brand machines can follow customer requires make OEM/ODM design. Also, if your have any project or tender issue, we can provide one-step purchasing solution. We gained SGS/ISO and the products have been CE/RoHs/FC/UL certificated. We are focus to develop and market our products through distributors. Our technical engineers are able to help you choose the most suitable products to meet your requirements. All products are guaranteed by warranty. Our machine has been greatly used by hos

AELAB Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer AA4530F
AELAB Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer AA4530F
AELAB Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer AA4530F
AELAB Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer AA4530F
AELAB Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer AA4530F
AELAB Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer AA4530F
AELAB Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer AA4530F
AELAB Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer AA4530F
AELAB Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer AA4530F

AELAB Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer AA4530F

Model NO.
AA4530F
Minimum order quantity:
1
+ Completely controlled by PC.
+ Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though use the optical signal for a long term.
+ Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.
+ Position adjusting: the best height of the flame burner and can automatically set the front and rear positions.
+ Fully automated wavelength scanning and peak searching.
+ Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout.
+ Deuterium lamp and self-absorption background regulation.
+ Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called.
+ Measuring method: flame absorption method and emission method.
+ Result printing: parameter printing, data result printing and diagram printing.
Quantity:

AELAB Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer AA4530F

Features:
+ Completely controlled by PC.
+ Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though use the optical signal for a long term.
+ Eight
 light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.
+ Position adjusting: the best height of the flame burner and can automatically set the front and rear positions.
+ Fully automated wavelength scanning and peak searching.
+ Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout.
+ Deuterium lamp and self-absorption background regulation.
+ Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called.
+ Measuring method: flame absorption method and emission method.
+ Result printing: parameter printing, data result printing and diagram printing.


Technical Specification :
Wavelength range190 – 900nm
Spectral bandwidth0.1, 0.2, 0.4, 1.0 and 2.0nm
Accuracy of the wavelength±0.15nm
Receptivity of the wavelength≤0.04nm
Base line stability≤0.002A/30min (Cu)
Characteristic viscosity0.02μg/ml/1% (Cu)
Checking limit0.004μg/ml (Cu)
Preciseness0.50%
Grating1800 lines/mm
InflamerAll-metal titanium burner
AtomizerEffective glass atomizer
Lamp stand8

D2 background correction ability
When the background is 1 A, the background ability should be deducted, not less than 50 times; self absorption background deduction method
Package size860mmx705mmx755mm (Main instrument)
1170mmx645mmx900mm ( Accessories)
Power source220V±22V AC
 
Flame System
Acetylene air burner100mm
Ignition dynamic baseline drift≤0.006A/30min
(Cu) Characteristic viscosity≤0.025μg/ml/1%
Related standard deviation of the accuracy≤0.5%(Cu, absorbance0.8A) (detection limit Cu≤0.008μg/ml)
Safety systemCan automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.
 
4510GF Graphite Furnace
The highest temperature3000
The largest temperature rising speed≥2000/S
Characteristic quantityCd≤0.5×10-12g Cu≤0.5×10-11g
AccuracyCu≤3% Cd≤3%
Size and weight730mm×625mm×700mm 79.3Kg
Safety systemOver current protection - Low air pressure alarm / protection Low cooling water flow alarm/protection
Power source and power220V±22V AC 7000W





 
  • AELAB Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer AA4530F.png:Downloads
  • AELAB Single Beam 8 Lamps Turret Atomic Absorption Spectrophotometer AA4530F 2.png:Downloads

Send Message

* clear input
* clear input
* clear input
* clear input
*
*
Preview on Mobile
X
customer-service Customer Service
whatsapp WhatsApp
skype Skype
message Message
go top Top
Scan the QR code Close
qr code
qrcode

Send Message

* clear input
* clear input
* clear input
* clear input
*
*
Choose language