AELAB GUANGZHOU CO.,LTD, A & E Lab Instruments (Guangzhou) Co.,Ltd510230About Us2504,No.2-6 Hongde Road, Guangzhou, Guangdong, China.AELAB Group major supply lab & medical instruments, we have our own brand and trading the machines together. AELAB own brand machines can follow customer requires make OEM/ODM design. Also, if your have any project or tender issue, we can provide one-step purchasing solution. We gained SGS/ISO and the products have been CE/RoHs/FC/UL certificated. We are focus to develop and market our products through distributors. Our technical engineers are able to help you choose the most suitable products to meet your requirements. All products are guaranteed by warranty. Our machine has been greatly used by hos

AELAB Gas Chromatograph GC112A
AELAB Gas Chromatograph GC112A
AELAB Gas Chromatograph GC112A
AELAB Gas Chromatograph GC112A
AELAB Gas Chromatograph GC112A

AELAB Gas Chromatograph GC112A

Model NO.
GC112A
Minimum order quantity:
1
+ 7-inch color touch screen, carrier/hydrogen/air channel flow (pressure) digital display.
+ Gas shortage alarm protection function; Heating control protection function (when opening the door of the column box, the motor of the column box fan and the heating system will shut down automatically).
+ Split flow/split ratio can be automatically controlled to save carrier gas.
+ Configure automatic sampler installation and positioning interface to match automatic sampler of various specifications.
+ The multi-core, 32-bit embedded hardware system ensures the reliable operation of the instrument.
+ One-button start function, with 20 groups of sample test mode memory function.
+ Using logarithmic amplifier, detection signal no cut-off value, good peak shape, extensible synchronous external trigger function, can be started by external signals (automatic sampler, thermal analyzer, etc.) at the same time the host and workstation.
+ It has perfect system self-check function and fault automatic identification function.
+ With 8 external event extension function interface, can be selected with various function control valves, and according to their own set time sequence work.
+ RS232 communication port and LAM network port, and the configuration of data acquisition card.
Quantity:
 

AELAB Gas Chromatograph GC112A

+ 7-inch color touch screen, carrier/hydrogen/air channel flow (pressure) digital display.
+ Gas shortage alarm protection function; Heating control protection function (when opening the door of the column box, the motor of the column box fan and the heating system will shut down automatically).
+ Split flow/split ratio can be automatically controlled to save carrier gas.
+ Configure automatic sampler installation and positioning interface to match automatic sampler of various specifications.
+ The multi-core, 32-bit embedded hardware system ensures the reliable operation of the instrument.
+ One-button start function, with 20 groups of sample test mode memory function.
+ Using logarithmic amplifier, detection signal no cut-off value, good peak shape, extensible synchronous external trigger function, can be started by external signals (automatic sampler, thermal analyzer, etc.) at the same time the host and workstation.
+ It has perfect system self-check function and fault automatic identification function.
+ With 8 external event extension function interface, can be selected with various function control valves, and according to their own set time sequence work.
+ RS232 communication port and LAM network port, and the configuration of data acquisition card.

Oven:
+ Content product: 22L
+ Temperature control range: 5~ 400at room temperature
+ Temperature control accuracy: ±0.1
+ Heating rate: 0.1 ~ 60/ min
+ Program temperature rise order: 9
+ Program heating repeatability: 2%
+ Cooling way: open the door after
+ Cooling speed: 10 mins (250~ 50)

Sampler Injector:
+ Temperature control range: 7~ 420at room temperature
+ Temperature control method: independent temperature control
+ Carrier gas flow control mode: constant pressure
+ Number of simultaneous installations: 3 at most
+ Type of injection unit: filling column, shunt
+ Split ratio: split ratio display
+ Cylinder pressure range: 0 ~ 400kPa
+ Cylinder pressure control accuracy: 0.1kPa
+ Flow setting range: H2 0 ~ 200ml / min , N2 0 ~ 150ml / min.
 
Flame Ionization Detector (FID):
+ FID, TCD optional
+ Temperature control: Max. 420
+ Number of simultaneous installations: 2 at most
+ Ignition function: automatic
+ Hydrogen flame ionization detector (FID)
+ Detection limit: 3×10-12 g/s (n-hexadecane)
+ Baseline noise: 5×10-14A
+Baseline drift: 6×10-13A
+Dynamic range: 107
+ RSD: 3% or less
+ Thermal conductivity detector (TCD) :
+ Sensitivity: 5000mVmL/mg (n-cetane)
+ Baseline noise: 0.05 mV
+ Baseline drift: 0.15mV / 30min
+ Dynamic range: 105
+ Supply voltage: AC220V±22V, 50Hz±0.5Hz
+ Power: 3000W

Optional Accessories:
+ N2000 chromatography workstation
+ Packed column
+ Capillary column
  • AELAB GC Spectrometer GC112A.png:Downloads

Send Message

* clear input
* clear input